Sump Pump GPH & Battery Backup Sizing Calculator
Enter your basement size, soil, and how far the discharge pipe climbs and runs. The calculator estimates storm inflow, adds pipe and elbow friction to your vertical lift, and shows which pump moves enough water at that head — plus how long a 12V battery backup keeps up when the power goes out.
Pump & Backup Sizing Calculator
Results update as you change any input. Measure vertical lift from the pit water level to the highest point of the discharge pipe, usually where it exits the rim joist.
Recommended Pump & Backup
At 11.3 ft of total dynamic head, a typical 1/3 HP pump moves about 1,892 GPH, 75% above the 1,080 GPH storm inflow. Compare pumps by their GPH at your head, not the 0-ft headline rating on the box.
1.5" quiet spring check valve + 3/16" anti-airlock weep hole
The backup pump runs about 82% of the time at storm inflow, so a 100 Ah battery's 4.6 hours of continuous pumping stretches to roughly 5.6 hours of outage coverage. Lighter rain stretches it further.
Pump output uses typical cast-iron submersible performance curves; always confirm against the GPH-at-head chart for the exact model. Inflow is an estimate — watching how often your pump cycles in a heavy storm is the best real-world measurement.
Why the GPH on the Box Is Not What Your Pump Delivers
Sump pump boxes advertise flow at 0 or 5 feet of head because that is the biggest number on the curve. Your pump never works there. It has to lift water from the pit to the highest point of the discharge line, and every foot of pipe and every elbow adds friction on top of that lift. The sum is the total dynamic head (TDH), and the only number that matters is the pump's GPH at your TDH.
On a typical 1/3 HP pump, that 11.3 ft of head cuts output from about 2,600 GPH at 5 ft to under 1,900 GPH. Replacing tight 90s with sweep elbows or 45s and keeping the horizontal run short keeps more of the rated flow.
Battery Backup Runtime: Continuous Hours vs. Storm Coverage
A 12V deep-cycle AGM battery should only be drawn down to about 20% of its capacity, so the usable energy is amp-hours × 12 volts × 0.8. A typical 12V backup pump draws about 210 watts while it runs. That gives the continuous pumping time: a 100 Ah battery runs the backup for about 4.6 hours nonstop.
Outage coverage is usually longer, because the backup only runs when the pit fills. If storm inflow is half of what the backup can pump, it runs about half the time and the same battery covers roughly twice as many hours. The catch is the reverse case: when inflow is higher than the backup's roughly 22 GPM, it runs nonstop and the water still rises. In heavy clay or high water table basements, plan for a high-capacity combination unit, a second battery, or a water-powered backup if you have municipal water pressure.
Backup Maintenance Checklist
- Test it quarterly. Unplug the primary pump and fill the pit with a bucket until the backup float trips.
- Watch the charger. A trickle charger fault light or alarm means the battery is not being maintained.
- Replace AGM batteries every 3–5 years. Capacity fades with age long before the battery fails completely.
- Give the backup its own check valve. A shared discharge without one lets the backup pump water back into the pit.
Frequently Asked Questions
Do I need a 1/3 HP or 1/2 HP sump pump?
Size the pump by the gallons per hour it delivers at your total dynamic head, not by horsepower alone. A typical 1/3 HP cast-iron submersible is enough for most basements with a lift of 10 feet or less and moderate groundwater: it still moves roughly 1,900–2,100 GPH at 10–11 feet of head. Step up to 1/2 HP when the discharge has to climb 12–15 feet or more, when the run to daylight is long, or when heavy clay and a high water table keep the pump cycling every few minutes in storms. A 3/4 HP high-head pump is for lifts approaching 20 feet. An oversized pump short-cycles and wears out faster, so the goal is the smallest pump that clears your storm inflow at your head with a margin.
How do vertical lift and 90-degree elbows reduce sump pump GPH?
Every sump pump has a performance curve: the higher it has to push water, the less water it moves, until it reaches shut-off head and moves nothing. Vertical lift (from the pit water level to the highest point of the discharge pipe) is the biggest part of that head. Friction adds to it: in 1.5-inch Schedule 40 PVC, plan on about 0.03 feet of head per foot of pipe and about half a foot per 90-degree elbow. A 9-foot lift with 25 feet of horizontal pipe and three elbows becomes about 11.3 feet of total dynamic head. On a typical 1/3 HP pump, that drops output from about 2,600 GPH at 5 feet to under 1,900 GPH. Using sweep elbows, fewer turns, and a larger discharge pipe on long runs keeps more of the rated flow.
How long will a battery backup sump pump run during a power outage?
A 12V deep-cycle AGM battery delivers roughly 80% of its rated amp-hours before it should be recharged, so a 100 Ah battery provides about 960 usable watt-hours. A typical 12V backup pump draws around 210 watts while running, which works out to about 4.6 hours of nonstop pumping. Because the pump only runs when the pit fills, real outage coverage is longer: if storm inflow is 13 GPM and the backup moves about 22 GPM, it runs roughly 59% of the time and that same battery covers close to 8 hours. If inflow is higher than the backup can pump, it runs continuously and the pit still rises, so the battery buys time rather than protection. Batteries lose capacity with age; test the backup and replace AGM batteries every 3–5 years.
Why does a sump pump need a check valve and a weep hole?
The check valve sits on the discharge pipe just above the pit and stops the water in the pipe from falling back into the pit each time the pump shuts off. Without it, the pump re-pumps the same water over and over, cycles more often, and wears out sooner. A spring-loaded "quiet" check valve closes before the water column slams it, which prevents the loud bang (water hammer). The weep hole is a 3/16-inch hole drilled in the discharge pipe between the pump and the check valve, angled down into the pit. It lets trapped air escape so the pump cannot airlock, a condition where it runs but moves no water, often after the pit runs dry. The small stream of water from the weep hole while the pump runs is normal.
Related Water Damage Tools & Guides
Sump pump failed: basement flooding triage
What to do first when the pump stops and water is rising.
Subfloor & flooring salvage calculator
Find out which basement flooring can be dried and which must come out.
IICRC S500 drying equipment calculator
Size air movers and LGR dehumidifiers for a wet basement.
Drywall flood-cut calculator
Find the 12", 24", or 48" cut line for finished basement walls.
First 60 minutes after water damage
Safety, shutoff, and documentation steps for a flooded basement.
State Farm sump pump coverage
Why sump overflow usually needs a water backup endorsement.
Sources used for this guide
This page is grounded in the public sources listed below.
Get Professional Help Now
Connect with a local water damage expert immediately.